Fleet Dashboard

Real-time overview of all battery assets

Live

Total Fleet

268

batteries deployed

Running

115

Idle

34

Charging

39

Non-Communicating

43

Active Alerts

76

Protections

51

Avg SOC

49%

Avg SOH

88.9%

Energy Delivered

27.5k

kWh total

SOC Distribution

Temp Distribution

Alerts & Protections

30 active

Low SOC warning

BAT-0013411:58

OVP (Over Voltage Protection)

BAT-0014311:34

OTP (Over Temperature Protection)

BAT-0003011:29

UVP (Under Voltage Protection)

BAT-0002711:01

OCP (Over Current Protection)

BAT-0011510:43

GPS signal lost

BAT-0014310:20

Communication timeout

BAT-0007810:02

Low SOC warning

BAT-0026109:55

Charging anomaly detected

BAT-0007809:39

Over-temperature detected

BAT-0020009:33

Charging anomaly detected

BAT-0000909:23

Low SOC warning

BAT-0020209:17

Charging anomaly detected

BAT-0016409:00

Current spike detected

BAT-0018409:00

Low SOC warning

BAT-0011908:41

SCP (Short Circuit Protection)

BAT-0018007:50

Over-temperature detected

BAT-0023807:27

SCP (Short Circuit Protection)

BAT-0013907:04

GPS signal lost

BAT-0014806:41

Cell voltage imbalance

BAT-0016806:21

UVP (Under Voltage Protection)

BAT-0003006:15

SCP (Short Circuit Protection)

BAT-0012205:55

Communication timeout

BAT-0004305:51

OTP (Over Temperature Protection)

BAT-0009205:18

GPS signal lost

BAT-0014805:17

SOH degradation threshold

BAT-0011005:09

Cell voltage imbalance

BAT-0020005:02

Over-temperature detected

BAT-0024303:50

Communication timeout

BAT-0020203:42

Charging anomaly detected

BAT-0017503:40

ML Insights

AI-powered battery diagnostics

1 critical2 warnings

Remaining Useful Life

~1,847 cycles remaining

Based on capacity fade analysis (0.012% per cycle) and current SOH of 100%, the average fleet battery has approximately 1,847 charge cycles before reaching 80% SOH threshold.

LSTM Degradation Model v2.1
89%

Anomaly Detection

3 batteries flagged

Isolation Forest detected abnormal cell voltage imbalance (>25mV spread) in ZEN-MH-0023, ZEN-KA-0041, ZEN-DL-0087. Recommend immediate inspection to prevent thermal event.

Isolation Forest + Autoencoder
94%

Usage Optimization

Charging pattern advisory

62% of fleet charges above 90% SOC regularly, accelerating calendar aging by ~15%. Recommend limiting charge to 85% SOC for non-critical vehicles to extend pack life by 200+ cycles.

Gradient Boosted Regressor
82%

Thermal Risk Prediction

12 batteries at elevated risk

Predictive thermal model shows 12 batteries in Hyderabad & Chennai zones are operating near 40°C ambient regularly. Projected 18% faster capacity degradation. Consider thermal management upgrades.

Random Forest Classifier
76%

Capacity Degradation Forecast

Fleet avg 92.3% SOH in 6 months

Exponential decay model forecasts average fleet SOH dropping to 92.3% over next 6 months at current utilization rates. 4 batteries may hit replacement threshold within 3 months.

Exponential Decay + Kalman Filter
85%

Cell Balancing Advisory

8 packs need active balancing

Cell voltage variance analysis shows 8 packs with >15mV dispersion trending upward. Recommend triggering BMS active balancing cycle during next overnight charge window.

Statistical Process Control
91%
Last inference: 2 min ago • 268 batteries analyzed